Digital Transformation in Energy & Decarbonization

Huawei Digital Power C&I GFM ESS Passes Extreme Ignition Test

Huawei

Huawei Digital Power’s Commercial and Industrial Hybrid Cooling Grid Forming Energy Storage System has successfully passed a stringent extreme ignition test witnessed by TÜV Rheinland. Conducted at a national key fire safety lab, the test is the industry’s first fire assessment of an ESS in compliance with the latest UL 9540A:2025 standard.

Extreme Challenge: Rigorous Test Environment

The test was designed to create the industry’s most demanding verification environment, evaluating the safety performance of ESSs under extreme ignition scenarios. A pack-level overcharge method was used to trigger simultaneous thermal runaway in 60 battery cells. Compared with tests involving only single or a few cells, the severity of this assessment increases exponentially.

Further rigor was ensured through the following conditions:

  1. The open-door ignition test method specified in UL 9540A:2025 is employed to maximize oxygen availability.
  2. All packs are fully charged to 100% SOC.
  3. All proactive and passive fire suppression systems are disabled during testing, requiring the ESSs to rely solely on their intrinsic design to withstand combustion at full energy capacity.

Proven Strength: Five-Level Protection System

Under these extreme conditions, Huawei’s C&I GFM ESS demonstrated outstanding safety performance, supported by its innovative five-level protection design.

  1. Inter-cell thermal isolation: It effectively slows down the thermal runaway propagation between cells, providing the first defense for system safety.
  2. All-metal pack enclosure: The enclosure can withstand temperatures higher than 1500°C, maintaining structural integrity even under intense fire to minimize damage.
  3. Positive-pressure oxygen blocking and directional smoke exhaust: This innovative design redirects combustibles, significantly reducing fire impact.
  4. Fireproof labyrinth design: All ESS sealing surfaces feature a labyrinth structure to effectively prevent flame spread.
  5. Enhanced container fire resistance: The container is armored to provide comprehensive fire protection.

Explore the Business Insights Journal for up-to-date strategies and industry breakthroughs!

Related posts

BrightNight Appoints Adam C. Peakes as CFO to Support Next Phase of Growth

PR Newswire

Carbon Direct & Microsoft Publish 2025 Criteria for CO₂ Removal

Business Wire

Volteras Raises $11.1 Mn Series A to Transform Energy and Mobility Data

PR Newswire